Skip to main content

Advertisement

Log in

Sensorineural hearing loss in patients with chronic otitis media

  • Otology
  • Published:
European Archives of Oto-Rhino-Laryngology Aims and scope Submit manuscript

Abstract

Chronic otitis media is generally associated with some degree of hearing loss, which is often the patient’s chief complaint. This hearing loss is usually conductive, resulting from tympanic membrane rupture and/or changes in the ossicular chain due to fixation or erosion caused by the chronic inflammatory process. When cholesteatoma or granulation tissue is present in the middle ear cleft, the degree of ossicular destruction is even greater. An issue that has recently gained attention is additional sensorineural hearing loss due to chronic otitis media. While the conductive loss can be minimized through surgery, sensorineural hearing loss constitutes a permanent after effect, attenuated only through the use of a hearing aid. However, a few groups have reported a decrease in sensorineural function in these patients as well. This survey study performed at a referral center evaluates the occurrence of sensorineural hearing loss in ambulatory patients with this disease. We reviewed the files of patients with unilateral chronic otitis media. One hundred and fifty patients met the inclusion criteria: normal otoscopy and normal hearing in the contralateral ear. Main outcome measure: bone-conduction threshold averages were calculated for frequencies of 500, 1,000, 2,000, 3,000 and 4,000 Hz, with comparison between the normal ear and the ear with chronic otitis media. Thresholds were examined separately for each frequency. The bone-conduction threshold averages for the normal side were lower than those for the ear with chronic otitis media. The threshold shift was statistically significant for each frequency (P < 0.0001, Student’s t test). There were differences between the groups when analyzed for age (500 and 1,000 Hz) or the presence of cholesteatoma (1,000 Hz). This study shows that chronic otitis media is associated with a decrease in cochlear function.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Noordzij JP, Dodson E, Ruth RA, Arts HÁ, Lambert P (1995) Chronic otitis media and sensorineural hearing loss: is there a clinically significant relation? Am J Otol 4:420–423

    Google Scholar 

  2. Papp Z, Rezes S, Jòkay I, Sziklai I (2003) Sensorineural hearing loss in chronic otitis media. Otol Neurotol 24:141–144

    Article  PubMed  Google Scholar 

  3. Goldstein BA, Newman CW (1999) Mascaramento clínico: tomando decisões. In: Katz J (ed) Tratado de audiologia clínica, 4th edn. Manole, São Paulo, pp 109–131

    Google Scholar 

  4. Musiek FE, Rintelmann WF (2001) Perspectivas atuais em avalição auditiva. Manole, São Paulo

    Google Scholar 

  5. MacAndie C, O’Reilly B (1999) Sensorineural hearing loss in chronic otitis media. Clin Otolaryngol 24(3):220–222

    Article  PubMed  CAS  Google Scholar 

  6. Lundman L, Santi PA, Morizo T, Hadara T, Junhn SK, Bagger-Sjoback D (1992) Inner ear damage and passage through the round window membrane of Pseudomonas aeruginosa exotoxin A in a chinchilla model. Ann Otol Rhinol Laryngol 101:437–444

    PubMed  CAS  Google Scholar 

  7. Cureoglu S, Schchern P, Paparella M, Lindgren R (2004) Cochlear changes in chronic otitis media. Laryngoscope 114(4):622–626

    Article  PubMed  Google Scholar 

  8. Engel F, Beatz R, Hellner J et al (1995) Breakdown of round window membrane permeability barrier evoked by streptolysin O: possible etiologic role in development of sensorineural hearing loss in acute otitis media. Infect Immunol 63:1305–1310

    CAS  Google Scholar 

  9. Pickett B, Shinn J, Smith M (1997) Ear drop ototoxicity: reality or myth? Am J Otol 18:782–791

    PubMed  CAS  Google Scholar 

  10. Jinn T, Kim P, Russel P et al (2001) Determination of ototoxicity of common otic drops using isolated cochlear outer hair cells. Laryngoscope 11:2105–2108

    Article  Google Scholar 

  11. Lundy L, Graham M (1993) Ototoxicity and ototopical medications: a survey of otolaryngologists. Am J Otol 14(2):141–146

    PubMed  CAS  Google Scholar 

  12. Linder T, Zwicky S, Brandle P (1995) Ototoxicity of ear drops: a clinical perspective. Am J Otol 16(5):653–657

    PubMed  CAS  Google Scholar 

  13. Kellerhals B (1978) Horschaden durch ototoxische Ohrtropfen. HNO 26:49–52

    PubMed  CAS  Google Scholar 

  14. Goycoolea MV, Muchow D, Schachern P (1988) Experimental studies on round window structure: function and permeability. Laryngoscope 98(Suppl 44):1–20

    PubMed  CAS  Google Scholar 

  15. Sahni RS, Paparella MM, Schachern PA, Goycoolea MV, Le CT (1987) Thickness of human round window membrane in different forms of otitis media. Arch Otolaryngol Head Neck Surg 113:630–634

    PubMed  CAS  Google Scholar 

  16. Schchern PA, Paparella MM, Duval AJII, Choo YB (1984) The human round window. Arch Otolaryngol 110:15–21

    Google Scholar 

  17. Juhn SK, Harnaguchi Y, Goycoolea M (1988) Review of round window permeability. Acta Otolaryngol Suppl 457:43–48

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sady Selaimen da Costa.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Costa, S.S.d., Rosito, L.P.S. & Dornelles, C. Sensorineural hearing loss in patients with chronic otitis media. Eur Arch Otorhinolaryngol 266, 221–224 (2009). https://doi.org/10.1007/s00405-008-0739-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00405-008-0739-0

Keywords

Navigation