Skip to main content
Log in

Characterization and use of the new NIST rapid pneumatic tube irradiation facility

  • Advances in Nuclear Instrumentation and Software
  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Recently a new rapid pneumatic tube facility was inserted into a long unused location in the NIST 20 MW nuclear reactor. This facility was designed and constructed specifically for rapid INAA using short lived activation products. Included is a computer controlled console which uses fast sensors to accurately measure the irradiation capsule flight time, and a loss-free counting system connected to a 32% efficient PHGe detector with a transistor reset preamplifier. Measurement of travel, times from end-of-irradiation to detector were 473±8 ms. Measurement of the thermal neutron fluence rate was 5.0·1013 n·cm−2·s−1. The other three pneumatic tubes in the NIST reactor have transfer times of 3 to 15 seconds, and no timing capability more accurate than human response. This new facility substantially improves our ability to accurately determine activation products with half-lives from 1 to 100 seconds. Characterization information reported on this new irradiation facility includes absolute fluence measurements, fluence rate variations within the capsule and variations with time, and determination of analytical sensitivities for fluorine-20 selenium-77m, and silver-110g.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R. R. Greenberg, H. M. Kingston, R. L. Watters, Jr., K. W. Pratt, Fresenius J. Anal. Chem., 338, (1990) 394.

    Article  CAS  Google Scholar 

  2. D. A. Becker, R. M. Lindstrom, J. K. Langland, R. R. Greenberg, J. Trace Microprobe Tech., 14 (1996), No. 1, 1.

    CAS  Google Scholar 

  3. R. M. Lindstrom, D. A. Becker, J. K. Langland, R. R. Greenberg, J. Radioanal. Nucl. Chem., 215 (1997) 47.

    Article  CAS  Google Scholar 

  4. D. A. Becker, NBS Tech. Note 548, U.S. Dept. Commerce, 6–23 (1970).

  5. D. A. Becker, P. D. LaFleur, J. Radioanal. Chem. 19 (1974) 149.

    CAS  Google Scholar 

  6. D. A. Becker, J. Radioanal. Chem., 110 (1987) 393.

    CAS  Google Scholar 

  7. W. N. McElroy, L. S. Kellogg, W. Y. Matsumoto, J. L. Jackson Hanford Engineering Development Laboratory, Monthly Progress Report, U.S. Atomic Energy Commission, Washington, DC, Oct. 1972, p. 1.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Becker, D.A. Characterization and use of the new NIST rapid pneumatic tube irradiation facility. J Radioanal Nucl Chem 233, 155–160 (1998). https://doi.org/10.1007/BF02389664

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02389664

Keywords

Navigation